Perma-Liner Industries (Singapore) Pte. Ltd.

News · November 2026 · Standards

DIN EN ISO 11296-4 is being replaced: one new standard for CIPP lining

ISO 11300-2:2026 brings sewers, pressure drains and water mains under a single standard for cured-in-place pipe.

The ISO 11296, 11297 and 11298 requirements for CIPP now sit in one standard, ISO 11300-2:2026.
The ISO 11296, 11297 and 11298 requirements for CIPP now sit in one standard, ISO 11300-2:2026.
Standard
ISO 11300-2:2026, first edition
Published
October 2026
Covers
CIPP lining of drains, sewers and water supply
EN and DIN adoption
By April 2027

Specifications for cured-in-place pipe (CIPP) have referred to DIN EN ISO 11296-4 for many years. That standard is now being replaced. In October 2026, ISO published ISO 11300-2:2026, the first edition of a single standard for CIPP lining with thermoset composite materials.

For CIPP, ISO 11300-2 cancels and replaces seven documents: ISO 11296-1 and ISO 11296-4 with its 2021 amendment, for non-pressure drains and sewers; ISO 11297-1 and ISO 11297-4, for drains and sewers under pressure; and ISO 11298-1 and ISO 11298-4, for water supply networks. The PE and PVC-U parts of the old series move to ISO 11300-1 and ISO 11300-3.

The new standard covers non-pressure and pressure drains and sewers, and water supply networks carrying water for human consumption, including raw water intake lines. It applies at service temperatures up to 50 °C for drains and sewers and up to 25 °C for water supply. For pressure networks, it covers fully structural (class A) and semi-structural (class B) liners, as defined in ISO 11295, that do not rely on adhesion to the existing pipe.

The content has also been revised. Definitions have been amended and new ones added. Thermoplastics membranes have a new material classification, and the classification of resin systems has been expanded. Manufacturers must declare more short-term mechanical characteristics. A new class D has been added to the classification of lateral connections. Flexural testing now refers to ISO 14125 only, and the curvature correction applied when testing curved samples has been revised.

Some things remain outside the scope. The standard does not apply to short lengths of CIPP used only for patch repairs of local defects. It does not set requirements or test methods for abrasion, jetting, cyclic loading or impact resistance.

In Europe, CEN approved EN ISO 11300-2 on 9 October 2026. National standards bodies must publish it, and withdraw conflicting national standards, by April 2027 at the latest. In Germany, this means DIN EN ISO 11300-2 will take over from DIN EN ISO 11296-4.

For asset owners and consultants, the practical step is to check which standard and edition your CIPP specifications and tenders refer to, and plan the move to ISO 11300-2. If you would like to talk through what the change means for a specification, contact us.

Sources: ISO 11300-2:2026 (DIN Media); the foreword and scope of ISO 11300-2:2026; the European foreword of EN ISO 11300-2:2026.

Contact

Tell us about your pipeline.

Share the location, pipe size and material, length and the problem you are seeing. We will reply with next steps.

Headquarters
Perma-Liner Industries (Singapore) Pte Ltd
1 Bukit Batok Crescent, #09-58
WCEGA Plaza, Singapore 658064
Telephone
+65 6710 4262
What do you need?

Your enquiry is sent directly to our office. We will reply by email. See our privacy policy.