Perma-Liner Industries (Singapore) Pte. Ltd.

Inspection · Sewer pumping main · Singapore

Sewer pumping mains, inspected by CCTV through the bends

A condition assessment survey of a sewer pumping main, with the pipe cleaned so the camera sees the full bore.

The work front in a housing estate, the team at the opened main in the valve chamber, and the CCTV crawler.
The work front in a housing estate, the team at the opened main in the valve chamber, and the CCTV crawler.
Asset
Sewer pumping main
Pipe
Ductile iron, with bends
Access
Through removed spool pieces
Survey
CCTV crawler, full bore

A sewer pumping main carries wastewater under pressure from a pumping station to the next point in the network. It runs full, it has no manholes along its length, and it cannot be inspected like a gravity sewer. A CCTV condition assessment shows what is happening inside the pipe: corrosion of the wall, deposits, joint defects and deformation. Owners use it to plan repair or renewal before the main fails.

Pumping mains are some of the hardest pipes to survey. The bore is tight, and the line changes direction through bends that a standard crawler cannot get round. There is no open access point. The way in is at a valve chamber, where bolted spool pieces have to be unbolted and lifted out before the camera can go in, then refitted afterwards.

The main also has to be taken out of service. That means planning the shutdown with the client in advance: the time window, isolation of the line, how the flow is managed while the main is off, and when the spools come out and go back in. Every step has to fit inside that window.

Even with the pumps stopped, the main is not empty. Stagnant sewage, sludge and debris settle in the pipe, especially at low points and bends. A camera pushed into that sees only water and the top of the pipe. The invert, where most damage starts, stays hidden, and the survey misses what matters most.

Perma-Liner has developed its own way of inspecting pumping mains. Our method takes the camera through the bends, and our cleaning process clears the stagnant water, sludge and debris before the survey begins. The camera sees the full bore, from crown to invert, with no standing water in the way. The joints, the pipe wall and any defects are recorded clearly, against their distance along the main.

The work is confined-space work. Every chamber entry is made under permit, with gas monitoring, forced ventilation, a gantry and winch for entry and rescue, and a barricaded work area kept clear of residents and traffic.

Every pumping main is different, and each one needs its own plan. If you have a pumping main that needs a condition assessment, talk to us to find out how we do it.

Confined-space set-up at the valve chamber: gantry and winch, ventilation and a barricaded work area.
Confined-space set-up at the valve chamber: gantry and winch, ventilation and a barricaded work area.
A work front beside a public footpath, kept compact and clearly barricaded.
A work front beside a public footpath, kept compact and clearly barricaded.
CCTV view along the main, with the pipe wall and a joint clearly visible.
CCTV view along the main, with the pipe wall and a joint clearly visible.

Figures are taken from the project records. Client and site names are withheld.

Contact

Tell us about your pipeline.

Share the location, pipe size and material, length and the problem you are seeing. We will reply with next steps.

Headquarters
Perma-Liner Industries (Singapore) Pte Ltd
1 Bukit Batok Crescent, #09-58
WCEGA Plaza, Singapore 658064
Telephone
+65 6710 4262
What do you need?

Your enquiry is sent directly to our office. We will reply by email. See our privacy policy.